External Notification Config Or Builder
Inheritors
Functions
Link copied to clipboard
True: Alert when the bell character is received (output)
Content copied to clipboard
bool alert_bell = 6;
Link copied to clipboard
True: Alert when the bell character is received (output_buzzer)
Content copied to clipboard
bool alert_bell_buzzer = 13;
Link copied to clipboard
True: Alert when the bell character is received (output_vibra)
Content copied to clipboard
bool alert_bell_vibra = 12;
Link copied to clipboard
True: Alert when a text message arrives (output)
Content copied to clipboard
bool alert_message = 5;
Link copied to clipboard
True: Alert when a text message arrives (output_buzzer)
Content copied to clipboard
bool alert_message_buzzer = 11;
Link copied to clipboard
True: Alert when a text message arrives (output_vibra)
Content copied to clipboard
bool alert_message_vibra = 10;
Link copied to clipboard
Enable the ExternalNotificationModule
Content copied to clipboard
bool enabled = 1;
Link copied to clipboard
The notification will toggle with 'output_ms' for this time of seconds.
Default is 0 which means don't repeat at all. 60 would mean blink
and/or beep for 60 seconds
Content copied to clipboard
uint32 nag_timeout = 14;
Link copied to clipboard
Optional: Define a tertiary output pin for an active buzzer
This is used in standalone devices to to match the UI.
Content copied to clipboard
uint32 output_buzzer = 9;
Link copied to clipboard
When using in On/Off mode, keep the output on for this many
milliseconds. Default 1000ms (1 second).
Content copied to clipboard
uint32 output_ms = 2;
Link copied to clipboard
Optional: Define a secondary output pin for a vibra motor
This is used in standalone devices to match the UI.
Content copied to clipboard
uint32 output_vibra = 8;
Link copied to clipboard
When true, enables devices with native I2S audio output to use the RTTTL over speaker like a buzzer
T-Watch S3 and T-Deck for example have this capability
Content copied to clipboard
bool use_i2s_as_buzzer = 15;